Build a Temperature and/or
Humidity Controlled Fan with a
Picaxe 08M2 Microcontroller
September 25, 2017 by Raymond Genovese
A Picaxe 08M2 microcontroller and an
HIH6030 sensor team up to easily
control a ventilation fan using
temperature or humidity or both.
We use a ventilation fan when we want to move
air. Sometimes we want to move air for exhaust
(such as a kitchen fan clearing cooking odors
away) or to bring in cooler air (such as a PC fan to
reduce internal component temperatures) or to
move moist air away (such as a bathroom fan).
Fans can be controlled manually with a simple on/
off switch and we can also automate their use. In
this project, we build an automated fan that is
controlled by a user temperature setting, a user
humidity setting, or both.
Circuit Schematic
To build the project, we construct a circuit that
uses a Picaxe 08M2 microcontroller to read a
Honeywell HIH6030 temperature and humidity
sensor . Based on a comparison between the user-
defined values programmed into the Picaxe
nonvolatile memory and the values read from the
sensor, a decision is made to switch the fan on or
off.
If a sensor error occurs, it turns the fan off and
sounds an alarm. The circuit also monitors the
speed of the fan and if it is not moving when it
should be, or if it is moving when it shouldn't be, it
will sound an alarm.
The complete circuit for the project is shown in the
schematic below.
Schematic for the project. Click to enlarge .
Project BOM
Component Description
M1 (Fan) Thermaltake Pure 20
U1 78L05 5 volt regulator (100 mA)
U2 Picaxe 08M2 microcontroller
U3 HIH6030-021-001 hum/tem senso
Q1 IRL540 MOSFET N-CH TO-220AB
SG1 Piezoelectric buzzer 5 volt
C1 1.0 µF polarized capacitor
C2,C3,C5 0.1 µF nonpolarized capacitor
C4 0.22 µF nonpolarized capacitor
D1 1N4001 diode
D2 1N914 diode
R1 10 kΩ resistor
R2 33 kΩ resistor
R3 4.7 kΩ resistor
R4,R5 2.2 kΩ resistor
R6 150 Ω resistor
*Note: Sources and prices for common
components (capacitors, diodes, resistors) vary.
Hardware
The Picaxe 08M2 microcontroller (left) and HIH6030 sensor
on a carrier board (right).
Microcontroller
The “brain” for the project is a Picaxe 08M2
microcontroller programmed using the Picaxe
BASIC language. The 8-pin device features 2048
bytes of program memory (up to 1800 program
lines), 128 bytes of RAM, and six port pins (C.0
through C.4 are I/O, C.5 is input only).
For the project, the port pins are dedicated to the
following functions (details follow):
C.0 – Operates a piezoelectric buzzer to
provide an alarm.
C.1 – I C, SCL.
C.2 – I C, SDA.
C.3 – Reads fan tachometer signal.
C.4 – Turns fan on/off using the MOSFET (Q1)
switch.
C.5 – Not used (tied to ground through R3).
Humidity and Temperature Sensor
The project uses a Honeywell HIH6030 to monitor
temperature and relative humidity. The chip has a
supply voltage range of 1.8V-5.5V and uses an I C
interface to communicate with a
microcontroller. R4 and R5 are the recommended
pullup resistors. Capacitors C4 and C5 also follow
the values recommended by Honeywell.
The device comes in a surface mount package
(SOIC-8) and, for the project, is soldered onto a
carrier board making it usable as a DIP-8 package.
Power supply for the project
Power Supply
A regulated 12V power supply (model F1650) that
previously served as a power supply for a laptop is
used for the project. The unit is fused and is rated
to provide 12V at up to 3.5A – plenty of power for
this application. This model is still readily available
(e.g., on eBay) and can be obtained on the used
surplus market as well. Of course, not all model
F1650 power supplies are necessarily equivalent
and you should check the output details of
whichever power supply that you use.
The 12V supply is used to operate the fan and also
provide 5V power. To implement the 5V supply, I
used the venerable 78L05 (U1) 5V regulator along
with capacitors C1 and C2. The 5V supply powers
the Picaxe controller (U2), the HIH6030 sensor
(U3), and the piezoelectric buzzer (SG1).
Fan
I used this fan from Thermaltake. The 200 × 200
× 30 mm fan’s specifications include 12V operation
and ~130 CFM. D1 is a “flyback” diode used to
suppress voltage spikes that occur across the
inductive load presented by M1, the fan’s motor.
Fan Tachometer
The fan used has three connections on the
cable: Vcc (+12V), ground, and tachometer out. On
the unit I used, the wires were color coded as red,
black, and yellow, respectively. The tachometer
signal comes from a Hall effect sensor internal to
the fan. Additionally, there are two magnets internal
to the fan. Normally the tachometer signal is at
12V. When a magnet passes the Hall effect sensor,
the signal switches to ground. It is configured as
an open collector output with a pullup resistor to
12V internal to the fan.
We want the 08M2 input port C.3 to read the
tachometer signal, but at 5V, not 12V. To
accomplish this, we use R3 pulled up to 5V and
diode D2 to prevent the 12V from reaching the
08M2 while preserving the pulses that correlate
with the RPM of the fan. Note also that, because
there are two magnets, there are two pulses per
revolution.
Not all fans with a “third wire” tachometer signal
work the same. I have seen ones where there was
no internal pullup resistor and I have even seen
ones where there was no internal connection at all!
It's a good idea to test the functionality of the
tachometer signal before using it in the project.
Piezoelectric buzzer (left) and IRL540 MOSFET (right)
Fan Control Switch
The fan is operated by a 08M2 output bit (C.4)
connected to the gate of Q1, an IRL540 N-channel
power MOSFET. Q1 is used in a "low side" driver
configuration such that it will sink the fan’s current
when the voltage of the gate, relative to its source
pin, which is at ground, is increased by just a few
volts.
The IRL540 is well-suited for the application
because when the gate is near +5V (relative to the
source), the device’s resistance is rated to be only
0.077Ω, and it is able to sink a much greater
amount of current than the rated 0.23A of the fan.
Thus, when the Picaxe output pin is set to a logic
level “high” (~5V), the fan turns on and when the
output pin is at a logic level “low” (<0.6V), the fan
is off.
R1 is used to pull down the voltage at the gate of
Q1 when the Picaxe output port is in a high
impedance state, such as during power up.
Piezoelectric Buzzer
SG1 is a generic 5V buzzer. I measured the current
drawn by the device at 5V as 24mA. Since that
amount is near the Picaxe port's maximum output
current, current-limiting resistor R6 is used. SG1 is
connected to Picaxe output C.0 and functions as a
notification/alarm buzzer. Even with R6, it is
suitably loud.
The project circuit on a breadboard: 12V components (left)
and 5V components (right).
Firmware
Before presenting the program code listing, some
explanation of the basic tasks that the software
must perform is in order.
Reading Humidity and Temperature Values
To thoroughly understand how to use the HIH6030
sensor, it is advisable to become familiar with a
technical note from Honeywell detailing I C
communications with the sensor (PDF here ).
The default I C address of the sensor is 0x27, and
Picaxe BASIC wants the 8-bit left-shifted value of
0x4E. When the device powers up, it will accept a
data byte of 0xA0 to put it into “command mode”,
if one is received within 10 milliseconds. Command
mode can be used to set alarms, read EEPROM
and even configure the default I C address. There
is a Honeywell technical note on command mode if
you want to know more (PDF here ). We are not,
however, using command mode at all for the
project and explicitly execute a software delay on
power up to prevent the possibility of entering
command mode.
We can read the sensor's temperature and relative
humidity values by first sending the device a
measurement request. To do this, we simply issue
a write to the slave address. The sensor responds
with an acknowledge (ACK), and the Master device
then generates a “STOP” condition. For Picaxe
BASIC, we have to send a data byte along with the
initial write command to complete the transaction.
Thus, we send a “dummy” data byte of 0xFF, which
is always ignored by the sensor.
After issuing a measurement request and waiting a
short time (~37 milliseconds) for the
measurements to complete, we can read the
sensor's values by retrieving four bytes of data as
illustrated below.
Data stream read from the HIH6030 sensor (figure courtesy
of Honeywell ). Click to enlarge .
The data stream contains status, humidity, and
temperature values. Status values can be 0b00 =
normal, 0b01 = stale data, 0b10 = in command
mode, and 0b11 = not defined. See the technical
note for a full explanation of the status codes. In
our project, the status value must be equal to 0b00
indicating a normal transaction. Any other received
status value indicates a sensor or transmission
error and will result in an alarm sounding in an
infinite loop.
The Picaxe will read the four values and store the
14-bit humidity value (after masking the status
bits) in one variable and the 14-bit temperature
value (after dividing the value by 4 to shift the bits
right two places) into another variable.
These raw humidity and temperature values will be
compared to the high and low humidity and
temperature values that the user has set in the
program to decide whether to turn the fan on or off.
While it is the raw values that the program uses, it
is necessary to understand the relationship between
the raw values and the RH percentage and degrees
(C) that they represent.
That relationship for percent relative humidity is
given by the formula below, where "Humcount" is
the 14-bit raw humidity value.
For temperature, the relationship is given by the
formula below, where "Temcount" is the 14-bit raw
temperature value.
Configuring the Fan’s On and Off Thresholds
For both humidity and temperature, the program
uses an “on” threshold and an “off” threshold. If the
sensor value equals or exceeds the “on” value, the
fan will turn on. If the fan is on and the value drops
to the “off” value, the fan will turn off. By separating
the threshold values, we prevent the fan from
rapidly oscillating around one value. This is referred
to as hysteresis.
To set the threshold values in the program, we
convert RH percentage and degrees (C) to raw
values that the program uses in the variables
HumH (high humidity threshold), HumL (low
humidity threshold), TemH (high temperature
threshold), and TemL (low temperature threshold).
For humidity: raw value = RH(%)/0.0061.Thus, if
you want to set the high RH threshold to 82% RH
and the low threshold to 74% RH:
82/0.0061 = 13442.62, set HumH = 13443
74/0.0061 = 12131.15, set HumL = 12131
For temperature: raw value = (degrees (C) +
40)/0.01007. Thus, if you want to set the high
temperature threshold to 29 degrees (C) and the
low threshold to 27.5 degrees (C):
(29+40)/0.01007 = 6852.04, set TemH=6852
(27.5+40)/0.01007 = 6703.08, set TemL=6703
Fan Operating Modes
The operating mode of the fan is set in firmware by
the user setting the symbol UMODE, which sets the
value of the program variable, MODE, in the Picaxe
code. Only values of 1, 2, or 3 are functional. The
fan will not operate with other values.
When MODE is set to 1, the fan will operate
based on the sensor temperature value. When
temperature, in sensor counts, equals or is
greater than the value set in the variable
"TemH", the fan will be switched on. When
temperature, in sensor counts, equals or is lower
than the value set in the variable "TemL", the
fan will be switched off.
When MODE is set to 2, the fan will operate
based on the sensor RH value. When RH, in
sensor counts, equals or is greater than the
value set in the variable "HumH", the fan will be
switched on. When RH, in sensor counts, equals
or is lower than the value set in the variable
"HumL", the fan will be switched off.
When MODE is set to 3, sensor values for both
temperature and humidity are used to control
the fan. That is, when either temperature or
humidity measures are at, or exceed, the upper
limits (TemH or HumH), the fan turns on. The
decision to turn the fan off in mode 3 is more
complicated and is detailed below.
For Mode 3, if the fan has been turned on as a
result of only temperature rising to the upper limit,
then when temperature decreases to the lower
limit, the fan turns off. Similarly, if the fan turns on
as a result of only humidity reaching the upper limit,
then when humidity decreases to the lower limit,
the fan turns off. The procedures are just like those
in modes 1 and 2, respectively.
When the temperature and humidity have both risen
to or beyond their respective upper limits, however,
we will turn the fan off only if both lower limits
have been met. To accomplish this, we track the
two measures independently. That is, we track the
characteristic (temperature and humidity) that
caused the fan to turn on using bits in the program
variable FMODE.
For example, if temperature rises to the upper limit,
FMODE bit 0 is set and the fan is turned on. If
humidity subsequently rises to the upper limit,
FMODE bit 1 is set (the fan is already on). Now,
suppose that temperature, but not humidity, falls to
the lower limit. In this case, we clear FMODE bit 0,
but the fan remains on because FMODE bit 1 is still
set. When humidity falls to the lower limit, we clear
FMODE bit 1. Now, the fan is turned off because
both bits 0 and 1 of FMODE are cleared.
Checking RPM of the Fan
The fan speed for the unit that I used is stated as
800 RPM in the specifications. I measured the fan
RPM for my unit, using two different frequency
counters, and the result was about 900 RPM. As
mentioned in the fan documentation,
“Specifications are subject to change without
notice”. I believe that this is such a case.
To measure the RPM in the project code, I used the
Picaxe BASIC “count ” command. The command
counts the number of low-to-high transitions on a
Picaxe input port bit (the project schematic uses
port bit C.3). For a 5-second period, the count was
at 151 ± a few counts. That comes out to 30.2
pulses per second or 1812 pulses per minute (at
4MHz, the speed of the 08M2). The fan has two
magnets that pass by the Hall effect sensor, so we
need to divide the number of pulses by 2 to get
RPM. Doing so gives a value of 906 RPM, which is
acceptably close to my other measurements that
indicated an RPM of ~900.
The program uses this feature to detect whether
the fan is actually turning when it is switched on.
That is, the program samples the fan RPM and
compares the number to a programmed minimum
value that is set in firmware using the
variable mRPM. The default for mRPM is 100, but
the value can be changed by the user. Thus, if RPM
is less than mRPM after the fan is switched on, we
assume a fan error.
We also use this feature to detect if the fan is
turning when it is switched off. That is, if RPM is
greater than mRPM after the fan is switched off, we
assume a fan error.
The fan does not have a brake; when it is switched
off, RPM values will decline over a few seconds
before reaching a value of 0. Additionally, when
first switched on, a small amount of time is
required before RPM reaches the normal peak
value. We have a 5-second delay in software
before we measure RPM for an additional 5
seconds. Thus, we can overlook start-up and shut-
down RPM values, while checking temperature and
humidity every 10 seconds.
Code
The code for the project is given below, and the file
can be downloaded at the end of the article.
001 ; AxeFan.bas-PICAXE code to
accompany the article -
002 ; "Build a temperature and/or
humidity controlled fan"
003 ;
004 ; *** This software is offered
stricly as- is with no warranties
005 ; whatsoever. Use it at your own
risk. ***
006 init:
007
;--------------------------------
008 ; User sets the following turn
on and turn off values for temperature
009 ; and humidity as 16 bit sensor
counts in decimal
010 SYMBOL TemH= 6852 ; 29 degrees
(C)
011 SYMBOL TemL= 6703 ; 27.5
degrees (C)
012 SYMBOL HumH= 13443 ; 82 % RH
013 SYMBOL HumL= 12131 ; 74 % RH
014 SYMBOL mRPM= 100 ;151=~ 900 RPM
full on
015 ; User sets the mode to
1=temperature only, 2 =humidity only,
3=both
016 SYMBOL UMode= 3
017
;--------------------------------
018 ; The SYMBOLS below are for
program variable use
019 SYMBOL HUM=W0 ; 16 bit
humidity
020 SYMBOL TEMP=W1 ; 16 bit
temperature
021 SYMBOL status=B4 ; HIH
status (must be 0)
022 SYMBOL Fstatus=B5 ; fan
bit status ( 0= off, 1= on )
023 SYMBOL MODE=B6 ; fan mode
024 SYMBOL FMODE=B7 ; to
track which (T or H) or both turned the
Fan on
025 ; FMODE bit 0=T
and bit 1 =H
026 SYMBOL RPM=W4 ; to measure
Fan RPM
027 ; Note: Fan= 4 =MOSFET G on C .4
028 SYMBOL Fan= 4;
029 ; Note: Buzzer= 0 =piezo on C .0
030 SYMBOL Buzzer= 0;
031 ; Note: RPMin= 3 =Fan tach on C .3
032 SYMBOL RPMin= 3
033
;--------------------------------
034 let MODE=UMode
035 ; get fan bit status,
Fstatus= 1 if fan GPIO is on
036 Fstatus=pinc .4
037 gosub FanOff ; should boot
up off but switch it to be sure
038 let Fstatus= 0
039 ; I2C address is $ 27 shifted=$ 4 e
040 hi2csetup I2CMASTER, $ 4 E,
i2cslow, i2cbyte
041 let B5=$ff ; dummy arg
042 pause 30 ; wait past
command window
043 gosub PU_tone
044
;--------------------------------
045 ; main loop
046 main: ;get temperature and
humidity
047 hi2cout (B5) ; wake up
kick to start measurement cycle
048 pause 60 ; wait for
measurement cycle (nominally 36.65 ms)
049 hi2cin (B1) ; Hum hi
050 hi2cin (B0) ; Hum low
051 hi2cin (B3) ; Tem hi
052 hi2cin (B2) ; Tem lo
053 let status=B1 & % 11000000 ;
get status bits
054 let B1=B1 & % 00111111
; mask status
055 let W1=W1/ 4 ; shift
temperature
056 ; if status is not 0 , we have a
read error indicating either a
057 ; transmission error or a sensor
error.
058 ; ** This results in an error
trap. **
059 if status<> 0 then
060 goto TerrorS
061 endif
062 ; handle fan on / off depending on
the operating mode
063 MODE1:
064 ; mode 1 is temperature only
065 if MODE = 1 then
066 if TEMP >=TemH then
067 gosub FanOn
068 endif
069 if TEMP <=TemL then
070 gosub FanOff
071 endif
072 endif
073 MODE2:
074 ; mode 2 is humidity only
075 if MODE= 2 then
076 if HUM >=HumH then
077 gosub FanOn
078 endif
079 if HUM<=HumL then
080 gosub FanOff
081 endif
082 endif
083 MODE3:
084 ; mode 3 is both humidity and
temperature
085 if MODE= 3 then
086 ; If fan is off, should
we turn it on ?
087 if Fstatus= 0 then
088 if TEMP >=TemH then
089 FMODE=FMODE| 1
;set b0
090 gosub FanON
091 endif
092 if HUM >=Humh then
093 FMODE=FMODE| 2
;set b1
094 gosub FanOn
095 endif
096 elseif Fstatus= 1 then
097 ; else
098 ; if fan is on should
we turn it off?
099 if TEMP <=TemL then
100 FMODE=FMODE& 2
;reset b0
101 endif
102 if HUM <=HumL then
103 FMODE=FMODE& 1
;reset b1
104 endif
105 if FMODE= 0 then
106 gosub FanOff
107 endif
108 endif
109 endif
110
111 next1:
112 ; get fan bit status, Fstatus= 1
if fan GPIO is on
113 Fstatus=pinc .4
114 ; delay for 10 seconds before
looping
115 pause 5000 ;
116 ; check fan RPM as part of the
10 sec delay
117 count RPMin, 5000 ,RPM
118 if Fstatus= 1 then
119 if RPM < mRPM then
120 goto TerrorF ; fan
error - RPM too low!
121 endif
122 elseif Fstatus= 0 then
123 ; else
124 if RPM >= mRPM then
125 goto TerrorF ; fan
error - RPM too high!
126 endif
127 endif
128 goto main
129
;--------------------------------
130 ; Error Traps (infinite loops)
131 ; sensor or transmission error -
give continuous fast beeps
132 TerrorS:
133 switchon Buzzer
134 pause 35
135 switchoff Buzzer
136 pause 100
137 goto TerrorS
138 ; Fan RPM eror - give continuous
slow beeps
139 TerrorF:
140 switchon Buzzer
141 pause 75
142 switchoff Buzzer
143 pause 300
144 goto TerrorF
145
;--------------------------------
146 ; subroutines
147 FanOn:
148 if pinc .4 = 0 then switchon Fan
endif
149 return
150 FanOff:
151 if pinc .4 = 1 then switchoff
Fan endif
152 return
153 PU_tone:
154 ; power up - three beeps
155 switchon Buzzer
156 pause 100
157 switchoff Buzzer
158 pause 100
159 switchon Buzzer
160 pause 100
161 switchoff Buzzer
162 pause 100
163 switchon Buzzer
164 pause 100
165 switchoff Buzzer
166 return
Program Structure Comments
Lines 8-16: User-defined values for symbols to set
program variables that control the fan.
TemH, TemL, HumH, HumL are the high and
low raw-data values for controlling the fan on/
off set points.
mRPM is the RPM value used to determine if
the fan is turning when on and not turning when
off.
UMODE sets the operation mode for the fan (1
= temperature only, 2 = humidity only, 3 = both).
Lines 17-32: Symbol definitions for program
variables.
Lines 33-43: Initialization.
Initialization of the I C interface.
Issue starting tone (three beeps).
Lines 44-128: Main loop.
Lines 47-61: Read HIH3060 sensor; evaluate
status bits and store humidity and temperature
raw-data values.
Lines 62-111: Decide on whether to turn the fan
on or off for the current operating mode.
Lines 116-127: Check for acceptable fan RPM
depending upon on/off status.
Lines 129-144: Error alarm traps (infinite loops).
Lines 132-137: Error alarm (fast beeps) if status
byte does not equal 0 (transmission or sensor
error).
Lines 139-144: Error alarm (slow beeps) if RPM
is below mRPM when fan is on or above RPM
when fan is off.
Lines 145-166: Utility subroutines.
Closing Thoughts
This project presents an economical and relatively
simple example of automating the control of a fan.
The implementation can be accomplished with just
a few ICs, primarily because the sensor and the
microcontroller are highly integrated devices. The
system is flexible in that it can be configured to be
controlled by temperature or humidity or the
combination of both temperature and humidity.
Additionally, the user can easily configure the
characteristics of the control parameters, changing
them to suit a variety of applications.
The source code for the project can be downloaded